Short circuit proof PCB transformer, separating transformer
PT 7,5/2/24 - Discontinued items - no longer available
Characteristics
General data
The PCB transformers of the PT series are equipped with an integrated overload protection via a PTC in the input and feature an additional screw fastening in the base plate for space-saving installation. The unique XtraDenseFill resin encapsulation process provides the transformers with permanent corrosion protection, high insulation value, and maximum electrical conductivity.
Benefits
› Separating transformer according to EN (IEC) 61558-2-1
› Minimal size with high performance
› With dual output coils for series or parallel connection
› Self-extinguishing encapsulation material
Product | Short circuit proof PCB transformer, separating transformer |
Order number | PT 7,5/2/24 |
Series | PT |
Power | 7.5 VA |
Input | 230 V |
Output | 2 x 24 V • 0.156 Aac |
Phases | 1 |
Frequency range | 50 Hz to 60 Hz |
Short-Circuit Losses | 2 W |
No-Load Losses | 0.77 W |
Short circuit voltage uk | 18.44 % |
EN Insulation class | B (130°C) |
UL Insulation class | class 105 |
Duty Cycle | 100 % |
Wire material | Copper |
Efficiency | 73 % |
General
Short circuit proof | conditionally short-circuit proof |
Switching group | Iii0 |
Cooling type | AN |
Environment
Ambient temperature | -20 °C to 40 °C / -4 °F to 104 °F |
Max. installation height | 2,000 m / 6,562 ft |
Protection and Safety
Protection type | IP 00 |
Protection class (prepared) | II |
Overvoltage category | III |
Degree of contamination | 1 |
Electrical Connections
Input terminal | Pin |
Output terminal | Pin |
Size and Weight
Width | 51 mm / 2.01 in |
Height | 36 mm / 1.42 in |
Depth | 43 mm / 1.69 in |
Weight | 0.285 kg / 0.628 lbs |
Low Voltage Directive | EN 61558-2-1 |
Approval cURus - Recognized | UL 5085-1/-2; CSA 22.2 |