Short circuit proof PCB transformer, separating transformer
VB 1,5/2/18 - Discontinued items - no longer available
Characteristics
General data
The PCB transformers of the VB series provide galvanic isolation of the primary circuit from the secondary circuit and are designed with a special construction to ensure absolute short-circuit safety. Additionally, they meet all requirements for supplying SELV (Safety Extra Low Voltage) circuits.
Benefits
› Separating transformer according to EN (IEC) 61558-2-1
› Minimal size with high performance
› With dual output coils for series or parallel connection
› Absolutely short-circuit proof
› Self-extinguishing encapsulation material
Product | Short circuit proof PCB transformer, separating transformer |
Order number | VB 1,5/2/18 |
Series | VB |
Power | 1.5 VA |
Input | 230 V |
Output | 2 x 18 V • 0.045 Aac |
Phases | 1 |
Frequency range | 50 Hz to 60 Hz |
No-Load Losses | 0.9 W |
EN Insulation class | B (130°C) |
UL Insulation class | class 105 |
Duty Cycle | 100 % |
Wire material | Copper |
Efficiency | 57 % |
General
Short circuit proof | inherently short-circuit proof |
Switching group | Iii0 |
Cooling type | AN |
Environment
Ambient temperature | -20 °C to 70 °C / -4 °F to 158 °F |
Max. installation height | 2,000 m / 6,562 ft |
Protection and Safety
Protection type | IP 00 |
Protection class (prepared) | II |
Overvoltage category | III |
Degree of contamination | 1 |
Electrical Connections
Input terminal | Pin |
Output terminal | Pin |
Size and Weight
Width | 32.8 mm / 1.29 in |
Height | 24.4 mm / 0.96 in |
Depth | 27.8 mm / 1.09 in |
Weight | 0.083 kg / 0.183 lbs |
Low Voltage Directive | EN 61558-2-1 |
Approval cURus - Recognized | UL 5085-1/-2; CSA 22.2 |
VDE Approval |
VDE 0570-2-x (DIN EN 61558-2-x) |