Control- and safety isolating transformer

STE 63/23/24

Characteristics

General data

The control transformers of the STE series ensure safe galvanic isolation of the primary circuit from the secondary circuit. The unique BLOCK IMPEX vacuum impregnation process provides excellent protection against external influences while reducing noise levels. Installation is simple and quick thanks to the innovative push-in terminal technology.

Benefits

 Control and safety isolating transformer according to EN (IEC) 61558-2-2 and EN (IEC) 61558-2-6

 Very good inrush behavior due to reduced inrush currents

 High power density through a compact design concept

 Primary side ±5% taps for voltage adjustment

 Touch-protected connection terminals according to UVV BGV A3

 With combination base plate for screw and rail mounting

Product Control- and safety isolating transformer
Order number STE 63/23/24
Series STE
Power 63 VA
Input 219 V / 230 V / 241 V
Output 24 V • 2.63 Aac
Phases 1
Frequency range 50 Hz to 60 Hz
Short-Circuit Losses 7.94 W
No-Load Losses 3.59 W
Short-Term Power / instantaneous output 175 VA
Short circuit voltage uk 9.15 %
EN Insulation class B (130°C)
UL Insulation class class 130
Duty Cycle 100 %
Wire material Copper
Efficiency 84.5 %
General
Short circuit proof not short-circuit proof
Switching group Ii0
Cooling type AN
Environment
Ambient temperature -20 °C to 40 °C / -4 °F to 104 °F
Max. installation height 2,000 m / 6,562 ft
Protection and Safety
Protection type IP 00
Protection class (prepared) I
Overvoltage category III
Degree of contamination 1
Electrical Connections
Input terminal Push-in terminal
Output terminal Push-in terminal
Terminal PE Flat plug connection
Size and Weight
Width 78 mm / 3.07 in
Height 88 mm / 3.46 in
Depth 85 mm / 3.35 in
Weight 1.22 kg / 2.69 lbs
General
TS35 rail mounting possible Ja
Low Voltage Directive EN 61558-2-2
EN 61558-2-6
Approval cURus - Recognized UL 5085-1/-2; CSA 22.2

Conrad Electronic SE

Product link

Premier Farnell Limited

Product link

This could also be of interest to you

STE 100/23/24
Control- and safety isolating transformer • 1ph • 100 VA • IN: 219-241 Vac • OUT: 24 Vac
Product details
STE 160/23/24
Control- and safety isolating transformer • 1ph • 160 VA • IN: 219-241 Vac • OUT: 24 Vac
Product details
ST 63/23/24
Control- and safety isolating transformer • 1ph • 63 VA • IN: 219-241 Vac • OUT: 24 Vac
Product details
ST 20/23/24
Safety isolating transformer • 1ph • 20 VA • IN: 219-241 Vac • OUT: 24 Vac
Product details
ST 100/23/24
Control- and safety isolating transformer • 1ph • 100 VA • IN: 219-241 Vac • OUT: 24 Vac
Product details
STU 63/24
Control- and safety isolating transformer • 1ph • 63 VA • IN: 230-520 Vac • OUT:  24 Vac
Product details