Toroidal transformers, safety isolating transformer
RTE 20/2x18 - Discontinued types - not for new designs
Characteristics
General data
The toroidal transformers of the RTE series enable space-saving use due to minimal size with maximum performance. The transformers feature overload protection thanks to the built-in thermal fuse and have a lightweight design. The connections can be soldered directly onto a PCB.
Benefits
› Safety isolating transformer according to EN (IEC) 61558-2-6
› Dual output coils for series or parallel connection
› Minimal no-load losses
› Excellent temperature behavior due to low magnetic stray field
› Very low noise field
Product | Toroidal transformers, safety isolating transformer |
Order number | RTE 20/2x18 |
Series | RTE |
Power | 20 VA |
Input | 230 V |
Output | 2 x 18 V • 0.556 Aac |
Phases | 1 |
Frequency range | 50 Hz to 60 Hz |
Short-Circuit Losses | 5.77 W |
No-Load Losses | 0.33 W |
Short circuit voltage uk | 16.3 % |
EN Insulation class | B (130°C) |
UL Insulation class | class 105 |
Duty Cycle | 100 % |
Wire material | Copper |
Efficiency | 76.6 % |
General
Short circuit proof | not short-circuit proof |
Switching group | Iii0 |
Cooling type | AN |
Environment
Ambient temperature | -20 °C to 40 °C / -4 °F to 104 °F |
Max. installation height | 2,000 m / 6,562 ft |
Protection and Safety
Protection type | IP 00 |
Protection class (prepared) | II |
Overvoltage category | III |
Degree of contamination | 2 |
Electrical Connections
Input terminal | Stranded wire |
Output terminal | Wire connection |
Size and Weight
Weight | 0.32 kg / 0.705 lbs |
Low Voltage Directive | EN 61558-2-6 |
Approval cURus - Recognized | UL 5085-1/-2; CSA 22.2 |