Toroidal transformers, safety isolating transformer

RKD 200/2x15

Characteristics

General data

The toroidal transformers of the RKD series enable space-saving use due to minimal size with maximum performance. The low magnetic stray field does not affect surrounding components and ensures excellent temperature behavior. The connections can be soldered directly onto a PCB.

Benefits

 Safety isolating transformer according to EN (IEC) 61558-2-6

 Lightweight

 Dual input and dual output coils for series or parallel connection

 Minimal no-load losses

 Very low noise field

Product Toroidal transformers, safety isolating transformer
Order number RKD 200/2x15
Series RKD
Power 200 VA
Input 2 x 115 V
Output 2 x 15 V • 6.67 Aac
Phases 1
Frequency range 50 Hz to 60 Hz
Short-Circuit Losses 15.3 W
No-Load Losses 1.22 W
EN Insulation class B (130°C)
UL Insulation class class 105
Duty Cycle 100 %
Wire material Copper
Efficiency 92.4 %
General
Short circuit proof not short-circuit proof
Switching group IIii0
Cooling type AN
Environment
Ambient temperature -20 °C to 40 °C / -4 °F to 104 °F
Max. installation height 2,000 m / 6,562 ft
Protection and Safety
Protection type IP 00
Protection class (prepared) II
Overvoltage category III
Degree of contamination 2
Electrical Connections
Input terminal Stranded wire
Output terminal Wire connection
Size and Weight
Width 115 mm / 4.53 in
Height 51 mm / 2.01 in
Depth 115 mm / 4.53 in
Weight 2.16 kg / 4.762 lbs
Low Voltage Directive EN 61558-2-6
Approval cURus - Recognized UL 5085-1/-2; CSA 22.2

Conrad Electronic SE

Product link

Premier Farnell Limited

Product link

This could also be of interest to you

RKD 225/2x15
Toroidal transformers, safety isolating transformer • 1ph • 225 VA • IN: 2 x 115 Vac • OUT: 2 x 15 Vac
Product details
RKD 160/2x15
Toroidal transformers, safety isolating transformer • 1ph • 160 VA • IN: 2 x 115 Vac • OUT: 2 x 15 Vac
Product details
RKD 200/2x18
Toroidal transformers, safety isolating transformer • 1ph • 200 VA • IN: 2 x 115 Vac • OUT: 2 x 18 Vac
Product details
RTE 200/2x15 - Discontinued types - not for new designs
Toroidal transformers, safety isolating transformer • 1ph • 200 VA • IN: 230 Vac • OUT: 2 x 15 Vac
Product details
RTE 225/2x15 - Discontinued types - not for new designs
Toroidal transformers, safety isolating transformer • 1ph • 225 VA • IN: 230 Vac • OUT: 2 x 15 Vac
Product details
RTE 160/2x15
Toroidal transformers, safety isolating transformer • 1ph • 160 VA • IN: 230 Vac • OUT: 2 x 15 Vac
Product details