Short circuit proof PCB transformer, safety isolating transformer

PT 4,5/2/12

Characteristics

Benefits

 Minimum size at high output

 Integrated overload protection using PTC in the input

 Also with dual output voltage for series or parallel connection

 Permanent corrosion protection, high insulation value and maximum electrical reliability thanks to XtraDenseFill resin encapsulation

 Self-extinguishing potting material

 Space saving installation thanks to additional screw mounting in the base plate

Product Short circuit proof PCB transformer, safety isolating transformer
Order number PT 4,5/2/12
Power 4.5 VA
Input 230 V
Output 2 x 12 V • 0.1875 Aac
Phases 1
Frequency range 50 Hz to 60 Hz
No-Load Losses 1.5 W
EN insulation class B (130°C)
UL Insulation class class 105
Duty Cycle 100 %
Wire material Copper
Efficiency 65 %
General
Short circuit proof conditionally short-circuit proof
Switching group Iii0
Cooling type AN
Environment
Ambient temperature -20 °C to 40 °C / -4 °F to 104 °F
Max. installation height 2,000 m / 6,562 ft
Protection and Safety
Protection type IP 00
Protection class (prepared) II
Overvoltage category III
Degree of contamination 1
Electrical Connections
Input terminal Pin
Output terminal Pin
Size and Weight
Width 37 mm / 1.46 in
Height 33 mm / 1.3 in
Depth 44 mm / 1.73 in
Weight 0.2 kg / 0.44 lbs
Low Voltage Directive EN 61558-2-6
Approval cURus - Recognized UL 5085-1/-2; CSA 22.2
VDE Approval

VDE 0570-2-x (DIN EN 61558-2-x)

Premier Farnell Limited

Product link

This could also be of interest to you

PT 7,5/2/12
Short-circuit proof PCB transformer
Product details
PT 4,5/2/15
Short-circuit proof PCB transformer
Product details
PT 4,5/2/9
Short-circuit proof PCB transformer
Product details
VB 3,2/2/12
Short-circuit proof PCB transformer
Product details