Low profile transformer, safety isolating transformer
FL 30/8
Characteristics
General data
The PCB transformers of the FL series impress with minimal height and maximum power density. With dual input and output coils, the transformers can be configured for series or parallel connections. Mounting is done using screw fastenings in the base plate.
Benefits
› Safety isolating transformer according to EN (IEC) 61558-2-6
› Minimal size with high performance
› Permanent corrosion protection, high insulation value, and maximum electrical reliability thanks to XtraDenseFill resin encapsulation
› Coil body with 2-chamber technology
› Self-extinguishing encapsulation material
Product | Low profile transformer, safety isolating transformer |
Order number | FL 30/8 |
Series | FL |
Power | 30 VA |
Input | 2 x 115 V |
Output | 2 x 8 V • 1.875 Aac |
Phases | 1 |
Frequency range | 50 Hz to 60 Hz |
No-Load Losses | 2 W |
Short circuit voltage uk | 20.6 % |
EN Insulation class | E (120°C) |
UL Insulation class | class 105 |
Duty Cycle | 100 % |
Wire material | Copper |
Efficiency | 81 % |
General
Short circuit proof | not short-circuit proof |
Switching group | IIii0 |
Cooling type | AN |
Environment
Ambient temperature | -20 °C to 40 °C / -4 °F to 104 °F |
Max. installation height | 2,000 m / 6,562 ft |
Protection and Safety
Protection type | IP 00 |
Protection class (prepared) | I |
Overvoltage category | III |
Degree of contamination | 1 |
Electrical Connections
Input terminal | Pin |
Output terminal | Pin |
Size and Weight
Width | 57 mm / 2.24 in |
Height | 35.8 mm / 1.41 in |
Depth | 68 mm / 2.68 in |
Weight | 0.55 kg / 1.213 lbs |
Low Voltage Directive | EN 61558-2-6 |
RoHS compliant | EN IEC 63000 |
Approval cURus - Recognized | UL 5085-1/-2; CSA 22.2 |
VDE Approval |
VDE 0570-2-x (DIN EN 61558-2-x) |